Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
2.
Nat Commun ; 13(1): 4337, 2022 07 27.
Article in English | MEDLINE | ID: covidwho-1960370

ABSTRACT

We report a live-attenuated SARS-CoV-2 vaccine candidate with (i) re-engineered viral transcription regulator sequences and (ii) deleted open-reading-frames (ORF) 3, 6, 7, and 8 (∆3678). The ∆3678 virus replicates about 7,500-fold lower than wild-type SARS-CoV-2 on primary human airway cultures, but restores its replication on interferon-deficient Vero-E6 cells that are approved for vaccine production. The ∆3678 virus is highly attenuated in both hamster and K18-hACE2 mouse models. A single-dose immunization of the ∆3678 virus protects hamsters from wild-type virus challenge and transmission. Among the deleted ORFs in the ∆3678 virus, ORF3a accounts for the most attenuation through antagonizing STAT1 phosphorylation during type-I interferon signaling. We also developed an mNeonGreen reporter ∆3678 virus for high-throughput neutralization and antiviral testing. Altogether, the results suggest that ∆3678 SARS-CoV-2 may serve as a live-attenuated vaccine candidate and a research tool for potential biosafety level-2 use.


Subject(s)
COVID-19 Vaccines , COVID-19 , Animals , Antiviral Agents , COVID-19/prevention & control , Cricetinae , Humans , Interferons , Mice , SARS-CoV-2/genetics , Vaccines, Attenuated , Virus Replication
3.
Clin Biochem ; 101: 19-25, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1682990

ABSTRACT

BACKGROUND: Current serological methods for SARS-CoV-2 lack adequate standardization to a universal standard reference material. Standardization will allow comparison of results across various lab-developed and commercial assays and publications. SARS-CoV-2 EURM-017 is human sera reference material containing antibodies directed against SARS-CoV-2 proteins, S1/S2 (full-length spike [S]), S1 receptor-binding domain (S1 RBD), S1, S2, and nucleocapsid (N) protein. The goal of this study was to characterize five antigen-specific serum fractions in EURM-017 for standardization of serology assays. METHODS: Five antigen-specific serum fractions were affinity purified, quantified, and PRNT50 titers compared. Standardization methods were established for two anti-S1 RBD (IgG and Total Ig) and one N protein assay. For the anti-S1 RBD assays, standardization involved determining assay index values for serial dilutions of S1-RBD anti-sera. Index values for the anti-S1 RBD IgG assay and PRNT50 titers were determined for 44 symptomatic COVID-19 patient sera. The index values were converted to EURM-017 ug/mL. RESULTS: Anti-sera protein content was as follows: S1 (17.7 µg/mL), S1 RBD (17.4 µg/mL), S1/S2 (full-length S) (34.1 µg/mL), S2 (29.7 µg/mL), and N protein (72.5 µg/mL). S1 anti-serum had the highest neutralization activity. A standardization method for S1 RBD anti-serum and an anti-S1 RBD IgG assay yielded the linear equation (y = 0.75x-0.10; y = index, x=µg/mL anti-serum). Patient sample index values for the S1-RBD IgG assay correlated well with PRNT50 titers (Pearson r = 0.84). Using the equation above, patient index values were converted to standardized µg/mL. CONCLUSIONS: Standardization of different lab-developed and commercial assays to EURM-017 antigen-specific anti-sera will allow comparison of results across studies globally due to traceability to a single standard reference material.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/standards , COVID-19/diagnosis , SARS-CoV-2/immunology , COVID-19/blood , COVID-19 Serological Testing/methods , Humans , Immunoassay/standards , Immunoglobulin G/blood , Reference Standards
4.
Cell ; 184(8): 2229-2238.e13, 2021 04 15.
Article in English | MEDLINE | ID: covidwho-1095902

ABSTRACT

The biosafety level 3 (BSL-3) requirement to culture severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a bottleneck for research. Here, we report a trans-complementation system that produces single-round infectious SARS-CoV-2 that recapitulates authentic viral replication. We demonstrate that the single-round infectious SARS-CoV-2 can be used at BSL-2 laboratories for high-throughput neutralization and antiviral testing. The trans-complementation system consists of two components: a genomic viral RNA containing ORF3 and envelope gene deletions, as well as mutated transcriptional regulator sequences, and a producer cell line expressing the two deleted genes. Trans-complementation of the two components generates virions that can infect naive cells for only one round but does not produce wild-type SARS-CoV-2. Hamsters and K18-hACE2 transgenic mice inoculated with the complementation-derived virions exhibited no detectable disease, even after intracranial inoculation with the highest possible dose. Thus, the trans-complementation platform can be safely used at BSL-2 laboratories for research and countermeasure development.


Subject(s)
COVID-19/virology , Containment of Biohazards/methods , SARS-CoV-2 , A549 Cells , Animals , Chlorocebus aethiops , Cricetinae , Genetic Complementation Test/methods , Genome, Viral , HEK293 Cells , Humans , Male , Mice , Mice, Transgenic , RNA, Viral , SARS-CoV-2/genetics , SARS-CoV-2/pathogenicity , SARS-CoV-2/physiology , Vero Cells , Virulence , Virus Replication
5.
Cell Host Microbe ; 27(5): 841-848.e3, 2020 05 13.
Article in English | MEDLINE | ID: covidwho-716611

ABSTRACT

The ongoing pandemic of COVID-19, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), underscores the urgency to develop experimental systems for studying this virus and identifying countermeasures. We report a reverse genetic system for SARS-CoV-2. Seven complimentary DNA (cDNA) fragments spanning the SARS-CoV-2 genome were assembled into a full-genome cDNA. RNA transcribed from the full-genome cDNA was highly infectious after electroporation into cells, producing 2.9 × 106 plaque-forming unit (PFU)/mL of virus. Compared with a clinical isolate, the infectious-clone-derived SARS-CoV-2 (icSARS-CoV-2) exhibited similar plaque morphology, viral RNA profile, and replication kinetics. Additionally, icSARS-CoV-2 retained engineered molecular markers and did not acquire other mutations. We generated a stable mNeonGreen SARS-CoV-2 (icSARS-CoV-2-mNG) by introducing this reporter gene into ORF7 of the viral genome. icSARS-CoV-2-mNG was successfully used to evaluate the antiviral activities of interferon (IFN). Collectively, the reverse genetic system and reporter virus provide key reagents to study SARS-CoV-2 and develop countermeasures.


Subject(s)
Betacoronavirus/genetics , Betacoronavirus/pathogenicity , Coronavirus Infections/virology , DNA, Complementary/genetics , Organisms, Genetically Modified/genetics , Organisms, Genetically Modified/pathogenicity , Pneumonia, Viral/virology , Animals , Antiviral Agents/therapeutic use , COVID-19 , Chlorocebus aethiops , Clone Cells , Coronavirus Infections/drug therapy , Genes, Reporter/genetics , Genome, Viral/genetics , Interferons/therapeutic use , Pandemics , Pneumonia, Viral/drug therapy , RNA, Viral/genetics , SARS-CoV-2 , Vero Cells/virology , Virus Replication/physiology
6.
Appl Biosaf ; 25(3): 150-156, 2020 Sep 01.
Article in English | MEDLINE | ID: covidwho-197758

ABSTRACT

Introduction: During pandemic situations like the one caused by the emergent coronavirus SARS-CoV-2, healthcare systems face the challenge of limited personal protective equipment and impaired supply chains. This problem poses a threat to healthcare workers, first responders, and the public, which demands solutions that can span the gap between institutional shortages and resupplies. Objectives: To examine the efficacy of autoclave-based decontamination for the reuse of single-use surgical masks and N95 filtering facepiece respirators (FFRs). This method is the most readily available form of decontamination in the hospital and laboratory settings. Methods: Three models of N95 FFRs and two procedural masks were evaluated in this study. A moist heat autoclave using four different autoclave cycles: 115°C for one hour, 121.1°C for 30 minutes, 130°C for two minutes, and 130°C for four minutes was used. After the autoclave process, the FFRs were NIOSH fit tested and particle counting was performed for both coarse particles of 5 micrometers (µM) and fine particles from 0.1µM to 1.0µM. Results: We observed negligible alterations in the functionality and integrity of 3M 1805 and 3M 1870/1870+ N95 FFRs after three autoclave cycles. Surgical masks also showed minimal changes in functionality and integrity. The 3M 1860 FFR failed fit test after a single autoclave decontamination cycle. Discussion and Conclusion: The study finds that specific surgical masks and N95 FFR models can withstand autoclave decontamination for up to three cycles. Additionally, the autoclave cycles tested were those that could be readily achieved by both clinical and research institutions.

SELECTION OF CITATIONS
SEARCH DETAIL